
Chapter 5 DFX
™
Pro Options
Pinpoint feature, automatically detunes for center location.
Self Adjusting Threshold or Auto-tune, automatically maintains threshold.
Assigns each V.D.I. target number its own special tone or sound.
Pinpoint or non-discriminate feature, increases pitch or tone with target strength.
Motion modes produce the same, or different volume, based on target depth.
Automatically updates Ground Balance during searching.
TRACK appears on right side of display during AUTOTRAC
Positive or negative AUTOTRAC
Prevents tracking the ground during target detection.
(Manual Ground Balance) Coarse viewing, or overriding automatic.
(Manual Ground Balance) Fine viewing, or overriding automatic.
Change V.D.I. (target reference numbers) accepted (detected), or rejected status.
Speeds EDIT by dragging ACCEPT or REJECT with ARROW controls.
Target samples can be used to show or teach ACCEPT discrimination.
Target samples can be used to show or teach REJECT discrimination.
Speeds target responses, so close together targets each respond.
How strongly the instrument rejects or breaks up on iron.
Degree the instrument is responsive to signals in the +95 (hot rock) category
Adjust signal sampling width thus the ideal loop/search coil sweep speed.
How much circuitry (high-pass fi ltering) used to separate ground/trash signals and targets.
Rejected V.D.I. numbers and ICONS do not appear on display.
Graphic display representation of metal targets, ON/OFF.
Response intensity to produce a display indication & 3rd V.D.I. digit@ 86 and higher.
Measurement of ground, or metal target, during pinpointing.
information collects over multiple loop passes.
Emphasizes common or predominate SignaGraph
Clears or fades noncurrent SignaGraph
Selects the intensity of the signal received from the loop.
30. 2 FREQUENCY (BEST DATA) -
Transmits and processes at both 3kHz and 15 kHz frequencies (salt eliminated).
Automatically chooses data from the most reliable frequency (based on both magnitude and phase) for each specifi c target.
31. 2 FREQUENCY (CORRELATE) -
Transmits and processes at both 3kHz and 15 kHz frequencies (salt eliminated).
Compares data at 3 kHz and 15 kHz. Target signals that do not provide reasonably predictable information at both are automati-
cally rejected. Iron typically doesn't compare predictably between frequencies, improved iron rejection can be expected.
32. V.D.I. (NORMALIZED) -
2 Frequency modes (Best Data and Correlate) automatically have V.D.I Normalized ON
as it is required for these modes to operate predictably. Differences at 3 kHz and 15 kHz skew the well known traditional (6.59
kHz) V.D.I. chart/numbers painted on the top of the DFX control box. Normalization recalculates signals for this traditional
V.D.I. number chart. OFF expands/compresses portions of this V.D.I. scale (depending on the 1 frequency used.).
Operates at 3 KHz providing for superior high iron mineral use (no salt present) particularly
for high conducting silver/copper alloys. Normalized ON maintains traditional (6.59 kHz V.D.I. chart/numbers. Normalized OFF
signifi cantly expands higher end of V.D.I. chart/numbers compressing lower end of the scale.
34. 1 FREQUENCY (15 kHz) -
Operates at 15 kHz providing in lower mineralized areas (no salt present) particularly
for lower conducting gold/nickel alloys. Normalize OFF signifi cantly expands lower end of V.D.I. chart/numbers compressing
Komentáře k této Příručce